- Color
- Retro-reflection and minimum areas
- Recommended configurations of the materials and design
GARMENT DESIGN AND REFLECTIVE PLACEMENT - A class 1 or a class 2 garment must now have reflective material in the shoulder area, which provides greater visibility when a worker is bending over, or at angles that could be potentially missed on a garment without “vertical” reflective material over the shoulders.
FLAME RESISTANT (FR) LABELING - The 107-2004 standard did not address flame resistant labeling. ANSI 107-2010 requires all flame resistant garments to be tested within at least 1 of 7 ASTM or NFPA test methods, including a description of the flame resistance criteria. If a manufacturer wants to mark high visibility apparel as being FR, the garment must meet one of the FR tests in the 107-2010 Standard and certify its conformance to the FR requirement. For specific test methods, a copy of the new 107-2010 Standard can be purchased directly from the ISEA.
RAINWEAR – There have been new testing requirements added for rainwear. Three different test methods will define rainwear as either water repellant, water resistant or water proof.
GARMENT SERVICE LIFE GUIDELINES - ANSI 107-2010 also attempts to help users determine garment service life. Areas to consider are:
- garment use
- type of garment
- environment
- laundering methods
- exposure to the environment
In addition, it references the U.S. Federal Highway Administration statement about high-visibility life expectancy. (Federal Register/Vol. 71 No. 226/Friday, November 24, 2006/rules and regulations/p. 67798